Authorised uvex Distributor — UK

Hearing protection that actually fits. Proven, not assumed.

The uvex xact-fit test system measures the real noise attenuation each worker receives — not just the theoretical SNR rating on the box. Fast, reliable, and a legal requirement under the Control of Noise at Work Regulations 2005.

2–5 min
Per person, both ears
Any earplug
Open system, no lock-in
2005 regs
Compliance documented
uvex xact-fit test system — portable hearing protection fit testing kit
uv
uvex PartnerAuthorised UK distributor
✓ uvex xact-fit
Why Fit Testing?

Certified PPE isn't enough. Fit is everything.

A CE-marked earplug with an SNR of 35dB doesn't mean your workers are getting 35dB of protection. Real-world attenuation depends entirely on correct insertion and individual ear anatomy.

Legal Requirement

Under the Control of Noise at Work Regulations 2005, employers must ensure hearing protection is effective for each individual. Fit testing is the recognised method to verify compliance — and document it.

SNR Isn't Enough

SNR ratings are laboratory averages. Real-world protection varies dramatically per individual. Incorrect insertion or poor fit can mean little or no actual protection — even with fully certified PPE.

Real Protection

Fit testing is the only reliable way to measure actual attenuation. It verifies proper fit, educates users on correct insertion, documents compliance, and personalises protection to each worker.

Introducing

The uvex xact-fit test system

A fast, reliable, user-friendly hearing protection fit-testing system that measures the real noise attenuation each worker actually receives — using the proven Real Ear Attenuation at Threshold (REAT) method.

uvex xact-fit test system hardware kit uvex xact-fit

Test. Verify. Protect.

The uvex xact-fit is an open system — it tests virtually any earplug on the market, with no modifications needed. That means you're not locked into a single brand or model. Every worker gets tested on the PPE they actually wear.

Using the scientifically validated Real Ear Attenuation at Threshold (REAT) method, the system delivers accurate, individualised attenuation data. Results are automatically uploaded to cloud-based software — no manual data entry, no lost paperwork.

✓
Tests any earplug brand
✓
REAT measurement method
✓
Bluetooth & wireless
✓
Both ears simultaneously
✓
Cloud-based software
✓
uvex onboarding training
Key Benefits

Built for industrial reality

Designed for H&S teams who need fast, reliable testing across multiple sites, shifts, and PPE types — without vendor lock-in.

Open System

Tests virtually any earplug on the market. No modifications, no brand lock-in. Your workers get tested on the PPE they actually wear.

Portable & Wireless

Bluetooth connectivity means you can test anywhere with an internet connection — on the factory floor, the construction site, or the warehouse.

Fast Results

Tests both ears simultaneously in just 2–5 minutes per person. No bottlenecks, no long queues — test an entire shift efficiently.

Cloud-Based

Automatic upload, regular software updates, and access from anywhere. Records are secure, searchable, and audit-ready.

How It Works

Three steps to verified protection

From initial enquiry to documented compliance — Howcroft Group and uvex handle every step.

1

Book a Demo

Contact Howcroft Group to arrange a uvex xact-fit demonstration at your site. We'll walk you through the system, answer your questions, and assess your testing needs.

2

On-Site Test

Our trained team conducts fit testing on-site using the portable xact-fit system. Each worker is tested on their actual earplugs — both ears, in just 2–5 minutes.

3

Receive Results & Records

Results upload automatically to the cloud. You receive individualised attenuation data, compliance documentation, and recommendations — all audit-ready.

What's Included

Everything in the hardware kit

A complete, portable testing solution — ready to deploy on any site, straight out of the case.

Tablet with pre-installed xact-fit app
Wireless headset
Spare batteries
Hygiene kit
Protective case
Travel case
PC Manager tool
uvex onboarding training
Who Needs This?

Sectors that depend on fit testing

If your workforce is exposed to hazardous noise levels, fit testing isn't optional — it's essential. The uvex xact-fit system serves every major industrial sector.

Manufacturing Construction Warehousing Automotive Food & Drink Pharmaceutical Oil & Gas Rail Defence
Compliance Assured

Control of Noise at Work Regulations 2005

Under these regulations, employers have a legal duty to ensure that hearing protection provided to employees is effective. The uvex xact-fit test system provides the documented, individualised attenuation data you need to demonstrate compliance — verifying that each worker's hearing protection delivers real protection in real conditions, not just on paper.

Read the HSE guidance on noise at work
⚠️
HSE Enforcement Priority 2025 / 2026
Hearing protection is under active HSE inspection right now.
75% of noisy workplaces failed to properly maintain hearing protection in HSE's 2025 inspection programme. Is your site inspection-ready?
Book a Fit Test Demo →
The HSE CUFF Framework

What HSE inspectors check on your site

When inspectors visit, they follow a structured four-point CUFF check. Failure on any point can result in an enforcement notice — or prosecution under the Control of Noise at Work Regulations 2005.

C

Condition

Is the PPE in good shape? Inspectors check for cracks, worn foam, and degraded seals — all of which destroy real-world attenuation.

U

Use

Is it worn correctly at all times in the noise zone? Workers removing protection even briefly is a common enforcement trigger.

F

Fit

Does it actually fit the individual? Poor fit from certified earplugs can mean near-zero real protection. Individual fit testing is the only proof.

F

Fit for Purpose

Has the correct protection level been selected? Both under- and over-protection are enforcement issues. Target: 75–80 dB at the ear.

75%
of noisy workplaces failed to properly maintain hearing protection in HSE 2025 inspections
63%
of workers had never been told what attenuation level their hearing protection actually provides
25-yr
old earplugs found in active use during HSE visits — still being issued, providing zero measurable protection
💡

The xact-fit solution: The uvex xact-fit test directly addresses the Fit point of the CUFF framework — providing documented, individual attenuation results for every worker. That's the evidence trail HSE inspectors are looking for, and the proof your workforce is genuinely protected.

HSE Campaign — Silica Dust

The invisible risk your workers may already be breathing in

Silica dust is generated whenever concrete, brick, stone, or ceramics are cut, drilled, or ground. The particles are up to 100 times smaller than a grain of sand — invisible, but able to penetrate deep into the lungs causing permanent, irreversible damage.

HSE describes silica as the biggest occupational health risk in construction after asbestos. The Silica Dust (Exposure) Bill, debated in Parliament in June 2026, signals further legislative tightening is on the way.

!
Causes silicosis — progressive lung scarring that worsens even after exposure stops
!
Classified as a Group 1 human carcinogen — a proven cause of lung cancer
!
500+ construction worker deaths linked to silica exposure in the UK annually
!
600,000 UK workers exposed every year — many without adequate RPE
Talk to us about RPE →
COSHH Workplace Exposure Limit (WEL)
0.1 mg/m³

8-hour time-weighted average. This is not a safe level — it is the legal maximum. Employers must reduce exposure as far below this as reasonably practicable.

Highest Risk Tasks
Cutting concrete Drilling masonry Grinding & sanding Demolition Dry sweeping Quarrying Stonework processing
HSE's Hierarchy of Control
1.Eliminate or substitute (low-silica materials)
2.Engineering controls (water suppression, LEV extraction)
3.Safe working practices (vacuum systems, segregation)
4.Fit-tested RPE — where risks can't be fully eliminated
Book a Demo

See the uvex xact-fit system in action

Arrange a no-obligation demonstration at your site. We'll bring the kit, show you how it works, and help you build a fit-testing programme that meets your compliance obligations.

✓
On-site demonstration — we come to you, anywhere in the UK
✓
Live testing — see real attenuation results in real time
✓
Compliance planning — tailored advice for your workforce and noise environment
✓
No vendor lock-in — open system, tests any earplug brand
Book a uvex xact-fit Demo
We'll respond within one working day. No obligation.

By submitting this form, you agree to be contacted by Howcroft Group regarding your enquiry. We never share your data with third parties.

✓

Thank you — your request is in.

Our team will be in touch within one working day to arrange your uvex xact-fit demonstration.